System Configuration
* However, it is not possible to directly restore type data backed up using Vision Backup-Tool with the previous product (Ver. 1) to V2 (Ver. 2). In this case, use the dedicated data conversion software (freeware) to convert the Ver. 1 type data for V2 use, then transfer it to V2 and perform a backup again.
Item | A210 MultiChecker V2 | A110 MultiChecker V2 | |
---|---|---|---|
CPU | 32-bit RISC CPU (high-speed processing version) |
32bit RISC CPU | |
Frame memory | 512 × 480 (pixels) × 256 gradations | ||
Operator interface | Menu selection by specialized keypad Menu selection using the key emulation function (ver. 2.2 or later). |
||
Monitor display | Change between Gray-scale memory, Gray-scale through, Binary memory (A/B/C/D/E/F), Binary through (A/B/C/D/E/F), Gray-scale NG, Binary NG (A/B/C/D/E/F) |
||
Processing | Gray-scale | 8-bit 256 gradations | |
Binarization | 6 groups of binary processing from the gray-scale memory (upper and lower threshold settings) |
||
Number of product types | 64 | 32 | |
Execution modes | Execute all mode: Execute all set checkers Automatic switch mode: Change the checker to be executed in accordance with the judgment output result User-defined mode: Specify the checker for execution when the start signal is input |
||
Inspection function |
Position and Rotation position adjustment function (per product type) |
Max. 96 Rotation position adjustment function |
Max. 48 X-Y position adjustment function |
Priority adjustment function, Multi-stage adjustment function, Sequence setting by matching, gray-scale edge, binary edge or feature extraction detection position | |||
Exposure adjustment (per product type) |
Max. 96 | Max. 48 | |
Shape: Rectangular, Slice level adjustment according to changes in the gray-scale data, Gray-scale average value detection and judgement | |||
Smart matching and matching (sub-pixel processing) |
Smart matching: Max. 96 per product type Equipped with post-detection differential processing function |
Matching: Max. 48 per product type |
|
Sub-pixel accurate multiple detection matching by gray-scale correlation processing Rotation by raster detection and raster detection position (ア30 degrees) Output: Number of detected items, Correlation numbers, Position, Angle Teaching registered changes can be imported from external source Smart matching (A210): Judgement learning function by the smart template |
|||
Gray-scale edge detection (sub-pixel processing) |
Max. 96 per product type | Max. 48 per product type | |
Scanning method: Single/Projection, Gray-scale Filter/Width function, Detection by sub-pixel unit Detection position: Start point/Start and End points/Largest differential/Multiple edge | |||
Gray-scale window (per product type) |
Max. 96 | Max. 48 | |
Shape: Rectangular/Polygonal/Oval, Mask Shape: Rectangular/Polygonal/Oval, Gray-scale average value detection and judgement | |||
Feature extraction (per product type) |
Max. 96 | Max. 48 | |
Shape: Rectangular/Polygonal/Oval, Mask shape: Rectangular/Polygonal/Oval, Image filtering, Labeling, Output values: Counter/Center of gravity (to one decimal place) /Area/Projection width/Principle axis angle |
|||
Binary window (per product type) |
Max. 96 | Max. 48 | |
Shape: Rectangular/Polygonal/Oval, Mask shape: Rectangular/Polygonal/Oval, Image filtering, White/Black pixel dot count and judgement | |||
Binary edge detection (per product type) |
Max. 96 | Max. 48 | |
Shape: Line/Plane, Filter/Width function, Start point edge detection | |||
Line ( per product type) |
Max. 96 | Max. 48 | |
Shape: Straight line/Polygonal line/Circle/Arc, Image filtering, White/Black pixel dot/land count and judgement | |||
Conversion data | 4 registers, Can quote to numerical calculation, Can convert numerical calculation result to actual distance, Base distance, Base pixel, Coefficient |
||
Numerical calculations (per product type) |
Max. 96 | Max. 48 | |
Sine, Cosine, Absolute differential, Projection distance, Arithmetic calculations (addition, subtraction, multiplication and division), Arctangent, Root, Distance between points, Specific substitution, Referencing of previous data, Output control |
|||
Judgement output | External output register (D): Max. 96 per product type Internal output register (R): Max. 96 per product type |
External output register (D): Max. 48 per product type Internal output register (R): Max. 48 per product type |
|
External interface |
Serial | RS232C: 2ch (max.115200bps) Compatible with Panasonic Industrial Devices SUNX PLC FP series, Mitsubishi MELSEC A Series/FX Series, Omron C series, and Allen-Bradley SLC 500 series (Ver 2.2 or later) |
|
Parallel | Input = 11points, Output = 14 points, Removable screw-down terminal block |
||
Inspection start | Image trigger (timing sensor unnecessary), External sensor timing, Repeat start | ||
Other | Display functions | Display item suppressing function (menu display hide function), Display image brightness modification, Image suppress function when setting checkers, Image rotation function when setting checkers (A210), Bright display of reject location, Rotational adjustment angle display (A210), Data monitor function, Display of image processed with image filter, Spreadsheet, Display list of checkers |
|
Marker function | Maximum of 8 graphics per product type, Shape: Straight line/Rectangle/Circle, Registered graphics are displayed on the main screen |
||
Setup support tools |
Image storage function |
30 screens | 8 screens |
Save/load function for inspection image (all screens/problem screens), Store images for reinspection/resetting, Windows-PC image save/load function |
|||
Debugging | Trap function, Image storage function | ||
Setup help | Focus setup, Aperture setup, Lighting adjustment, Gray-scale profile monitor, Recommended slice level display, Input monitor, Forced output function |
||
Moving object inspection | Double-speed random camera (progressive), Flash, Electronic shutter used | ||
Camera support | High-speed random camera (progressive): ANM831, Standard camera: ANM832, Composite video (NTSC) input used (however the connection requires one port) |
||
Number of support cameras | 2 | 1 | |
Operating voltage | 24 V DC less than 0.9 A | 24 V DC less than 0.7 A | |
Setup data backup | Image data and setup data can be saved to a Windows PC using Vision Backup Tool Ver. 2 |
* Type data saved in the previous controller of the MICRO-IMAGECHECKER A Series (Ver. 1) cannot be directly restored to V2 using the Vision Backup-Tool. In this case, you will need the dedicated data conversion software (freeware) to convert the Ver. 1 type data for V2 use. If you require the data conversion software or information about how to use it, please contact your dealer.
Be the first to review “A210 / A110 MultiChecker V2”